All Products
Items 1651 to 1700 of 4271
£ 1,000.00 (ex. VAT) 1 in stock
Grant C1GR Immersion Chiller Lab
ITEM-53143
Grant C1GR Immersion Chiller Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Microlas GeoLas Q-Plus Excimer Laser Ablation System IC-PMS Lab
ITEM-38070
Microlas GeoLas Q-Plus Excimer Laser Ablation System IC-PMS
This system was removed from a university laboratory where it was surplus to requirements.
It is in very good cosmetic condition and powers on. We were able to operate the PC and run the Geolas Plus software but it has not been tested further.
List of installed programs:
- Geolas Plus
- Geolas.bmp
- Wago Profibus
- Camtasia Recorder
- Camtasia Producer
- Camtasia Player
System Components:
- Lambda Physik Compex 102 laser, Serial No. 0206E7773
- Lambda Physik Lasertechnik laser controller, Serial No. OE 662, Software CTERN 1.6
- Dell 1907FP monitor, Serial No. CN-0CC3000-64180-64J-3AES
- Ergotron monitor stand
- Qtronix keyboard Scorpius-35, Serial No. 000500127
£ 1,000.00 (ex. VAT) 1 in stock
Qiagen PyroMark Q96 ID And PyroMark Q96 Workstation Lab
ITEM-41642
Qiagen PyroMark Q96 ID And PyroMark Q96 Workstation Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
This item also includes the following:
Pyromark Q96 Lab station with plastic liquid container
£ 1,000.00 (ex. VAT) 1 in stock
Chemometec A/S NucleoCounter Model NC-200 Automated Cell Counter System Lab
ITEM-37995
Chemometec A/S NucleoCounter NC-200 Automated Cell Counter System Lab
This system was removed from a university lab where it was surplus to requirement.
Both the Chemometec A/S NucleoCounter NC-200 and Laptop are in very good cosmetic condition and powered up, we are unable to test them further at our facility.
Please note that this system does not include the software required to operate but the original laptop is included as it may have useful hardware.
Nucleocounter C-200
Serial No. 9000201112003520
Lenovo Thinkpad T15 laptop
Windows 10 operating system
Serial No. PF-2J1PMV
Also includes the following:
Included:
2 x Low-voltage power supplies
1 x Data lead
£ 1,000.00 (ex. VAT) 1 in stock
Illumina MiSeq Benchtop Gene Sequencing System Lab
ITEM-25248
Illumina MiSeq Benchtop Gene Sequencing System Lab
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has not been tested further.
It is in good cosmetic condition with minor marks from use.
Operating Conditions: 19°C to 25°C (66°F to 77°F).
The system also includes:
1 x Logitech Wireless Keyboard & Mouse.
8 x Used MiSeq Flow Cells in containers.
1 x 96 Well Plate.
1 x Spare FSE Fluidics Kit 15013841S.
7 x HiSeq Flowcell Gaskets 15011631.
1 x Ultra-Low Universal Lid.
1 x Illumina GenomeStudio v1.7 Software disc.
£ 1,000.00 (ex. VAT) 1 in stock
Varian 450-GC GC Gas Chromatograph with CP-8400 Autosampler Lab
ITEM-25049
Varian 450-GC GC Gas Chromatograph
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good cosmetic condition with minor marks.
Filters:
1x Moisture Filter CP1791
1x Oxygen Filter CP17970
£ 1,000.00 (ex. VAT) 1 in stock
Newport Anti-Vibration Table 90x60x88cm
ITEM-56443
Newport Anti-Vibration Table 90x60x88cm
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition with no damage present.
£ 1,000.00 (ex. VAT) 1 in stock
Nuaire NU-437-400E Class II Safety Cabinet Lab
ITEM-56384
Nuaire NU-437-400E Class II Safety Cabinet Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
Last Service: 27/3/25
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
OHAUS Frontier 5714 Centrifuge Lab
ITEM-58405
OHAUS Frontier 5714 Centrifuge – Functional Unit, No Rotor Included, PAT Failed
This centrifuge is being sold on behalf of a client where it is surplus to requirements.
The client has confirmed that the unit is in excellent working condition and fully functional. However, it failed its most recent PAT test. The reason for the PAT failure is unknown and may relate to a simple electrical check or lead issue rather than a functional fault.
It is therefore listed as Spares/Repair.
Please note that the centrifuge does not include the rotor or tube-holding accessory.
Includes:
OHAUS Frontier 5714 Centrifuge
UK mains cabling, where applicable
User manual
Limited service records, where available
£ 1,000.00 (ex. VAT) 1 in stock
Hitachi U-2800 UV/VIS Spectrophotometer Lab
ITEM-56175
Hitachi U-2800 UV/VIS Spectrophotometer Lab
This item was removed from a facility where it was surplus to requirement.
It powers on, we are unable to test it further at our facility.
£ 1,000.00 (ex. VAT) 1 in stock
Corning Flame Photometer 410 Lab
ITEM-55593
Corning Flame Photometer 410 Lab
This item was removed from a facility where it was surplus to requirement.
It powers on, we are unable to test it further at our facility
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Oxford Instruments C28232 Superconducting Magnet System
ITEM-56680
Oxford Instruments C28232 Superconducting Magnet System w/ Helium Gauge & Cables
This system was removed from a facility where it was surplus to requirement.
While this was removed from a working system, it is sold for spares/repairs
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Memmert IP 55 Plus Peltier Cooled Incubator Lab
ITEM-55346
Memmert IP55 Plus Peltier Cooled Incubator Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Haake K10 Recirculating Water Bath w/ DC 10 Controller Lab
ITEM-51282
Haake K10 Recirculating Water Bath w/ DC 10 Controller Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Trafalgar Cleaning Equipment Wolf3 Leaf & Litter Vacuum with Trolley
ITEM-51812
Trafalgar Cleaning Equipment Wolf3 Leaf & Litter Vacuum with Trolley
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Waters 1525µ Binary HPLC Pump Chromatography Lab
ITEM-56197
Waters 1525µ Binary HPLC Pump Chromatography Lab
This item was removed from a facility where it was surplus to requirement.
It powers on, we are unable to test it further at our facility.
£ 1,000.00 (ex. VAT) 1 in stock
Deben Cool Stage LEO-1400VP for Scanning Electron Microscope Lab
ITEM-50417
Deben Cool Stage LEO-1400VP for Scanning Electron Microscope Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
This item was removed from a ZEISS SUPRA 55 Scanning Electron Microscope systen. it was working when last used.
£ 1,000.00 (ex. VAT) 1 in stock
Leitz Labovert FS Microscope w/ 4 x Objectives PHACO 4x/10x/20x/32x Lab
ITEM-47409
Leitz Labovert FS Microscope
This item was removed from a university laboratory where it was surplus to requirements.
The microscope is in good cosmetic condition overall, with some surface marks from general use.
All mechanical and optical components function as intended.
Please note that a slide holder is not fitted to the stage.
Includes:
- 1 x Leitz EF4/0.12 160/- objective
- 1 x Leitz EF L20/0.30 PHACO 1a 160/1.5 objective
- 1 x Leitz EF L32/0.40 PHACO 1a 160/1.5 objective
- 1 x Leitz EF L10/0.25 PHACO 1a 160/- objective
- 2 x Leitz PERIPLAN 10x/18 eyepieces
£ 1,000.00 (ex. VAT) 1 in stock
Scanlaf Mars 1500 Class 2 Biohazard Safety Cabinet Lab
ITEM-36706
Scanlaf Mars 1500 Class 2 Biohazard Safety Cabinet
This item was removed from a university where it was surplus to requirement.
This is in good working order and in good cosmetic condition with marks from use.
Fan hours - 18990
£ 1,000.00 (ex. VAT) 1 in stock
Perkin Elmer MultiProbe II Plus HTEX w/ Gripper Intergration System and PC Lab
ITEM-49884
Perkin Elmer MultiProbe II Plus HTEX w/ Gripper Intergration System and PC Lab
This was removed from a laboratory environment where it was surplus to requirements.
The system powers on, displays a green status light, and produces normal operating sounds. It appears to be in good cosmetic condition, with several accessories clipped into place.
A PC is included, running WinPREP software, however no further functional testing has been carried out beyond power-on checks. Operational status and calibration are not guaranteed.
System details:
- MultiProbe II
- Model: AMP8E01
- Serial No: 431295
- Gripper
- Model: AMPGRE1
- Serial No: 431296
- PC & Display
- Dell OptiPlex 960 running Windows XP
- Samsung S22E200B monitor
£ 1,000.00 (ex. VAT) 1 in stock
Jenway 7305 Spectrophotometer Lab
ITEM-50040
Jenway 7305 Spectrophotometer Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
Please note; The power supply is not included.
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific UltiMate 3000 SRD-360 & Dionex UVD-3000 UV Detector
ITEM-50923
Thermo Scientific UltiMate 3000 SRD-3600 & Dionex UVD-3000 HPLC
This system was removed from a facility where it was surplus to requirement.
Both units power on.
Please note: There is no power supply included for the SRD-3600. (Requires a 24v Centre Positive Power Supply)
£ 1,000.00 (ex. VAT) 1 in stock
CW Specialist Equipment Humidity Cabinet Model AB7
ITEM-58427
CW Specialist Equipment Humidity Cabinet Model AB7
This equipment is being offered on behalf of a client, where it is now surplus to requirements.
The humidity cabinet is suitable for controlled environmental storage, conditioning or testing applications where humidity and environmental control are required.
The cabinet is in working order.
The client has advised they are able to bubble wrap the item only. Buyers should make their own arrangements for appropriate collection, lifting, palletisation, crating and transport.
Includes;
1 x Humidity Cabinet Model AB7
Specifications;
Model: AB7
Normal terms and conditions do not apply to this item, which is non-returnable and non-refundable.
£ 1,000.00 (ex. VAT) 1 in stock
Sequenom Agena MassARRAY Analyzer 4 System RS1000, PHX-1 & Accessories
ITEM-39706
Sequenom Agena MassARRAY Analyzer 4 System RS1000, PHX-1 & Accessories
This was removed from a university lab where it was surplus to requirements.
The system powers up and everything communicates but we were unable to test it further at our facility. The touchscreen on the nanodispense does not work, but we have replaced it with a monitor, mouse and keyboard. There is also a complete peripheral setup provided for the inbuilt PC in the PHX-1 system.
Included in the system are;
Sequenom Agena MassARRAY Analyzer 4 PHX-1
Model: PHX-1
Serial#: PX10060104
Sequenom Agena MassARRAY Nanodispenser RS1000
Model: RS1000
Serial#: 10P0413RS-01
The system also includes the following:
Windows XP Software Disc
NI Vision Deployment Engine for One User
MassARRAY Nanodispenser RS-1000 User's Guide v1.2.1
WebPAM Software Disc
FastTrak TX2300/TX4300 Quick Start Guide
Various Replacement parts (shown at end of slide)
Various Plates for plate reader.
£ 1,000.00 (ex. VAT) 1 in stock
Siemens Immulite 2000 Immunoassay System Lab
ITEM-38940
Siemens Immulite 2000 Immunoassay System
This was removed from a university lab where it was surplus to requirements.
The item powers on and runs through initialisation steps, the built-in computer boots up and has Immulite 2000 Version 6.9 Software installed. The touchscreen works.
It is in good cosmetic condition with minor marks.
We powered it with the provided UPS.
Included with it are;
AMETEK Powervar
Model - ACDEF3000-22
PN - 17302-02R
Accessories/Consumables:-
4 x Packs of Reaction Tubes (1000 per pack) REF - LRXT
12 x Sample Racks
Immulite 2000/2000 XPi System Software/Release Notes V.6.7
Tool box
£ 1,000.00 (ex. VAT) 1 in stock
BD Becton Dickinson LSR II Flow Cytometer Lab
ITEM-36938
BD Becton Dickinson LSR II Flow Cytometer
This was removed from a university lab where it was surplus to requirements.
The unit powers up but we were unable to test it further without a PC and software. The lab informed us when it was last used a few years ago, it was still working.
The unit is in overall good cosmetic condition with marks from use. There is a crack in the front and the right-hand cover and the left-hand door doesn't close fully.
2 x One AC
Model - CBS2120
PN - 011-526
SN - 0129 - 6308/0129-6304
Becton Dickinson Closed Waste Container
Alloy Products Corp 316L Waste Container (Lid doesn't fit)
SN - 115443-007
Table not included.
£ 1,000.00 (ex. VAT) 1 in stock
LUDL Microscope Stage w/Controller/Filter Wheel/Prior Keypad & Controller
ITEM-44702
LUDL Electronic Products MAC22 Controller System with Accessories
These items were removed from a university lab, where they were surplus to requirement.
All included items are in good cosmetic condition, power status where applicable is stated below.
Included is the following:
- LUDL Electronic Products MAC22 Automatic Controller
- 7-inch enclosure
- Part No.: 73002001
- Serial No.: 122330
- Status: Powers on
- LUDL 6-Position Filter Wheel
- Part No.: 99A075
- Serial No.: 119374
- LUDL Stage
- Part No.: 99S008-N23-NE
- Serial No.: 127742
- Prior Scientific Orbit Piezo Drive Controller
- Model Type: HPIEZO
- Serial No.: 25389
- Status: Powers on with included 24V power supply
- Ecopac 24V Power Supply
- Model No.: SA60-24V
- Prior Scientific Instruments Orbit CS100K Filter Wheel Keypad
- Keyspan USB Dual Port Converters/Adaptors
- Quantity: 2
- Part No.: USA-28X B
- Cables
- 2 x RS232 Cables labeled 'Stage X & Stage Y Ludl'
- 1 x Cable labeled 'Ludl RS232 Scope 4'
- 1 x Cable labeled 'To RS232 on Ludl 3'
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Zeiss LSM 510 Meta Confocal Microscope Laser Lab
ITEM-55979
Zeiss LSM 510 Meta Confocal Microscope Laser Lab
This item was removed from a facility where it was surplus to requirement.
The previous owner stated ti is faulty, though they did not elaborate on the fault.
It is therefore listed as Spares/Repair.
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific Robotics Enclosure Cabinet S-MAS9036-000-00 Lab
ITEM-39949
Thermo Scientific Robotics Enclosure Cabinet S-MAS9036-000-00 Lab
This enclosure was removed from a university where it was surplus to requirement.
This listing is the enclosure only and does not include the tables it sits on. Refer to the red highlight featured on the diagram.
It originally housed a Thermo Scientific™ Spinnaker™ Microplate Robot System which is not included.
The measurements for the assembled enclosure are as follows:
Length x 448cm
Width x 152cm
Height x 118cm
This item includes various brackets and fixings as seen, but we are unable to confirm if all the required items are included.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
De Vere 504 Enlarger Stand with Baseboard & Hardware Head Not Included S/R
ITEM-50083
De Vere 504 Enlarger Stand with Baseboard & Hardware – Head Not Included
This item was removed from a facility where it was surplus to requirements.
It is in reasonably good cosmetic condition. The enlarger head is not included, so the unit could not be powered on or tested.
The listing includes the baseboard/desk, timer stabiliser, and bolts/fixings.
Board Dimensions: 81 × 107 cm
External Dimensions:
- Length: 110 cm
- Width: 107 cm
- Height: 220 cm
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Kendro Heraeus HERAcell CO2 Incubator
ITEM-55614
Kendro Heraeus HERAcell CO2 Incubator
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 6 in stock
Truvox Cimex Cyclone Range CR48 Floor Scrubber Polisher
ITEM-61001
Truvox Cimex Cyclone Range CR48 Floor Scrubber Polisher
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
Please note that we have multiples of this unit in stock. You may not receive the one in the photos but will receive one in near-identical working and cosmetic condition. If you would like to see photos of the exact unit you are receiving upon purchase before it is shipped, we would be happy to provide this.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Perkin Elmer TurboMatrix 40 Headspace Autosampler
ITEM-58473
Perkin Elmer TurboMatrix 40 Headspace Autosampler
This item was removed from a facility where it was surplus to requirement.
It has failed the Visual PAT, and is therefore listed as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Precise Automation Cartesian PP100 Microplate Robotic Arm lab
ITEM-56439
Precise Automation Cartesian PP100 Microplate Robotic Arm lab
This item was removed from a facility where it was surplus to requirement.
It failed to power on, it is therefore listed as Spares/Repair.
£ 1,000.00 (ex. VAT) 1 in stock
Planer Kryo 550-16 Controlled Rate Freezer w/ LNP 4 Pump, PC & Software
ITEM-58688
Planer Kryo 550-16 Controlled Rate Freezer w/ LNP 4 Pump, PC & Software
This system was removed from a facility where it was surplus to requirement.
It is in good working order.
Includes;
- PC w/ DeltaT Kryo Software Installed
- Various User Manuals
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Lovibond/ Liebherr TC 140 Thermostatic Controlled Lab Incubator
ITEM-58459
Lovibond/ Liebherr TC 140 Thermostatic Controlled Lab Incubator
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
Last Service: 15/11/2022
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific Midi 40 Model 3404 CO2 Incubator
ITEM-61701
Thermo Scientific Midi 40 Model 3404 CO2 Incubator
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Agilent 7683 Series AutoSampler G2614A Lab
ITEM-50489
Agilent 7683 Series AutoSampler G2614A Lab
This item was removed from a facility where it was surplus to requirement.
It is in very good cosmetic condition and powers on, we are unable to test it further at our facility.
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Thermo Scientific HERAcell 150 Incubator Lab
ITEM-56189
Thermo Scientific HERAcell 150 Incubator Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
Last Service: 27/06/24
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Memmert BE 500 Laboratory Incubator
ITEM-61006
Memmert BE 500 Laboratory Incubator
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Edwards Auto 306 Thermal Evaporator Coating System Lab
ITEM-56177
Edwards Auto 306 Thermal Evaporator Coating System Lab
This system was removed from a facility where it was surplus to requirement.
The system powers on. However, the previous owner has advised that it is currently unable to achieve a high vacuum.
As a result, this item is being sold for spares or repair.
The previous owner also confirmed that the carbon rods used with the system were not exposed to any contaminants.
£ 1,000.00 (ex. VAT) 1 in stock
Sorvall TST 41.14 41000 Rpm Centrifuge Tube Swinging Rotor
ITEM-57787
Sorvall TST 41.14 41000 Rpm Centrifuge Tube Swinging Rotor
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition.
£ 1,000.00 (ex. VAT) 1 in stock
Beckman Coulter JA-14 Fixed Angle Rotor 14000 RPM Lab
ITEM-51641
Beckman Coulter JA-14 Fixed Angle Rotor 14000 RPM Lab
This item was removed from a facility where it was surplus to requirement.
It is in good cosmetic condition and remains untested.
£ 1,000.00 (ex. VAT) 1 in stock
Oxford High-Stability DC Magnet Power Supply
ITEM-56854
Oxford High-Stability DC Magnet Power Supply
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Binder Model BD115 Incubator Lab
ITEM-56857
Binder Model BD115 Incubator Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
£ 1,000.00 (ex. VAT) 1 in stock
Miltenyi Biotec AutoMACS Pro Separator Cell Sorter Lab
ITEM-58468
Miltenyi Biotec AutoMACS Pro Separator Cell Sorter Lab
This item was removed from a facility where it was surplus to requirement.
It is in good working order.
Last Service: 10/2025
autoMACS pro software: 2.4.5.0
Panel software: AMP_02_01_03
Includes;
- 2 x Chill 50 tube racks and a reagent 4 tube rack
NEW ITEM
NEW ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Binder FD-S 115 Drying Oven Lab
ITEM-61743
Binder FD-S 115 Drying Oven Lab
This item is being sold on behalf of a laboratory equipment supplier where it is surplus to requirements.
The oven is brand new and unused and has not been unpacked from its original manufacturer's shipping case.
The system is located in Horley, Surrey and can be packaged for transport in its original shipping case.
RECERTIFIED ITEM
RECERTIFIED ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Snijders ECD01E Climate Chamber Lab
ITEM-58037
Snijders ECD01E Climate Chamber Lab
This item was removed from a facility where it was surplus to requirements.
The unit is in good working order.
It is fitted with 14x Sylvania BriteGro UV bulbs.
Please note, 4x bulbs appear to be non-functional.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Votsch VCL 7010 Environmental Test Chamber
ITEM-54613
Votsch VCL 7010 Environmental Test Chamber
This item was removed from a facility where it was surplus to requirements.
The chamber powers on; however, the touchscreen does not operate correctly due to a Votsch software fault. The unit also requires servicing, as the humidity control is not functioning correctly.
Due to these issues, the chamber has not been fully tested and is therefore being sold as Spares/Repair.
SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 1,000.00 (ex. VAT) 1 in stock
Leica DM IRB Inverted Microscope, Incubation Chamber, EBQ 100 & Hot Air Blower
ITEM-51592
Leica DM IRB Inverted Microscope with Incubation Chamber, EBQ 100 Lamp Supply, Hot Air Blower & Cameras
This system was removed from a university laboratory where it was surplus to requirements.
This is an older, heavily used system and is being sold as-is as a project. It is generally operational but will require significant cleaning, servicing and general TLC to bring it into better working order.
The system is in fair overall cosmetic condition for its age and use. There is a substantial amount of old grease present across the microscope body and controls, which will require stripping and cleaning to free up the mechanisms. Orange staining is also visible on the slide stage and within the incubation chamber.
The microscope, Leica EBQ 100 lamp power supply and hot air blower all powered on and have **PAT passed (Class 1)**.
The Cairn Uniblitz shutter supply powers on and the shutter operates. The illumination within the power switch is intermittent.
The hot air blower operates as expected and has been tested above the stated 18°C starting temperature. Due to the way the system heats, reaching higher incubation temperatures such as 37°C would require an extended warm-up period and was not fully tested to this temperature.
The microscope controls require attention. The **coarse focus is currently inoperative**, while the fine focus is functional. X and Y stage adjustment operates but is stiff. The objective turret/objectives are also extremely stiff and could not be safely removed for detailed inspection. The fitted objectives nevertheless appeared optically clear during a brief test using a sample slide.
The eyepieces have been removed and cleaned and appear free from scratches.
Two cameras are included but were not tested due to the lack of a compatible PC/interface system.
Given the age, heavy previous use, stiff controls and servicing requirements, this system is recommended for a buyer prepared to undertake cleaning, lubrication and refurbishment. It is therefore listed as Spares/Repair.
The system consists of:
1 x Leica DM IRB Inverted Microscope
- Fitted with incubation chamber and slide stage
- Orange staining present
- Coarse focus inoperative
- Fine focus functional
- X/Y stage movement functional but stiff
- Controls/mechanisms require cleaning and removal of old grease
1 x Leica EBQ 100 Lamp Power Supply
- Powers on
Items 1651 to 1700 of 4271