SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 600.00 (ex. VAT) 1 in stock
Bigneat Ductless Fume Hood Model - PR1506 Lab Spares/Repairs
ITEM-44761
*Potentially worth looking into Password protected features*
Bigneat Ductless Fume Hood Model PR1506
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in good cosmetic condition.
The LED lights are functional. Airflow is audibly operational; however, an 'airflow low' alarm activates every 5 minutes due to completely depleted filters, which need replacing.
Airflow fluctuates between 0.34 and 0.14 M/S
We have deemed this spares/repairs due to the low airflow.
Specifications:
- Model: PR1506
Includes:
- LED lights

£ 600.00 (ex. VAT) 1 in stock
Beckman Coulter JA-17 Fixed Angle Rotor 14x50ml 17000RPM Lab
ITEM-46144
Beckman Coulter JA-17 Fixed Angle Rotor 14x50ml 17000RPM Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.

£ 600.00 (ex. VAT) 1 in stock
Statebourne Biostor 5 Liquid Nitrogen Cryogenic Storage Tank/Dewar Lab
ITEM-46187
Statebourne Biostor 5 Liquid Nitrogen Cryogenic Storage Tank/Dewar Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonably good cosmetic condition, we are unable to test it at our facility.

£ 580.00 (ex. VAT) 1 in stock
Nickel Electro Clifton 56L NE2-56D Water Bath Lab
ITEM-35646
Nickel Electro Clifton 56L NE2-56D Water Bath
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. (It was tested with a temperature probe, not included).
It is in good cosmetic condition with minor marks.
Capacity- 56L
Temperature range: ambient +5 to 100˚C
Electric Supply: 230V 50/60Hz
Serial number- 98307

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 575.00 (ex. VAT) 1 in stock
New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair
ITEM-36992
New Brunswick Scientific Innova 4230 Refrigerated Incubator Shaker Spares/Repair
This was removed from a university lab where it was surplus to requirements.
The unit powers but requires a replacement compressor and recharge as well as a new drive belt.
It is sold for spares/repairs.

£ 575.00 (ex. VAT) 1 in stock
Sanyo MSE Harrier 18/80 Refrigerated Centrifuge with 6000rpm Rotor Lab
ITEM-30455
This Sanyo MSE Harrier 18/80 Refrigerated Centrifuge was removed from a university lab where it was surplus to requirements.
The unit powers up and is in reasonably good cosmetic condition with marks from use.
It is in full working order. The rotor spins up to 6000rpm and the refrigeration works and has been tested at 4˚C and -9˚C.
MSE Rotor 43124-141
Max RPM - 6000
4 x Buckets
4 x Yellow Adaptors hold 1 x 50ml tube each

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 570.00 (ex. VAT) 1 in stock
Sartorius Genius Series ME215S Precision Laboratory Balance Scales Lab Faulty
ITEM-35674
Sartorius Genius Series ME215S Precision Laboratory Balance Scales
This was removed from a university lab where it was surplus to requirements.
The unit powers up but is showing Error 105
"'Key is stuck Release key or Key pressed when switching on Replace the keypad overlay; the Moisture Analyzer Short circuit in the application PCB or 105 the K key is defective Replace K key ”Checkerboard” pattern s key was pressed when turning displayed continuously on the Genius or is stuck'"
It is in otherwise excellent cosmetic condition and is supplied with the manual.
It is sold for spares/repairs.

£ 555.00 (ex. VAT) 1 in stock
Genlab LCI/12V/DIG/SMC Laboratory Incubator Lab
ITEM-38914
Genlab Model LCI/12V/PDIG Lab Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. (Digital thermometer not included)
4 Shelves - 60 x 60cm

£ 550.00 (ex. VAT) 1 in stock
Genlab Prime PRI/150 Laboratory Incubator Lab
ITEM-38908
Genlab Prime PRI/150 Laboratory Incubator
This was removed from a working lab where it was surplus to requirements
The unit powers up and is in full working order. It is in good cosmetic condition with minor marks.
2 Shelves - 49 x 48cm

£ 550.00 (ex. VAT) 1 in stock
Genlab LCI/12V/DIG/SMC Lab Incubator
ITEM-38913
Genlab Model LCI/12V/PDIG Lab Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. (Digital thermometer not included)
3 Shelves - 60 x 60cm

£ 550.00 (ex. VAT) 1 in stock
Sanyo MSE Mistral 2000R Refrigerated Benchtop Centrifuge with 4500rpm Rotor Lab
ITEM-30547
This Sanyo MSE Mistral 2000R Refrigerated Benchtop Centrifuge was removed from a university lab where it was surplus to requirements.
The unit has been tested and is in working order. The RPM could be set up to 6500 but the rotor would only run up to 4500rpm.
It was tested with a digital thermometer (not included).
When the temperature was set to 4˚c, the thermometer read 5˚c
When the temperature was set to -4˚c (minimum) the thermometer read -5˚c
There is a Rotor inside with 4 x Buckets and 2 x Yellow 50ml Adaptors.
It is in reasonably good cosmetic condition but has some minor marks from use.

£ 540.00 (ex. VAT) 1 in stock
Genlab Model LCI/12V/PDIG Lab Incubator
ITEM-38912
Genlab Model LCI/12V/PDIG Lab Incubator
This was removed from a university lab where it was surplus to requirements.
The unit powers up and is in good working order. (Digital thermometer not included)
7 Shelves - 61 x 61cm

£ 535.00 (ex. VAT) 1 in stock
B Medical Systems Plasma Storage Laboratory Freezer FR 410 G Lab
ITEM-32032
B Medical Systems Plasma Storage Laboratory Freezer FR 410 G
This was removed from a lab where it was surplus to requirements. We are told it was barely used by the client.
The unit powers up and has been tested with a digital thermometer (not included) to -41˚C.
It is in excellent cosmetic condition.
Internal dimensions - L50 W66 H87cm
2 Shelves 63 x 47cm
2 Drawers 59 x 46 x 6cm

£ 525.00 (ex. VAT) 1 in stock
Jouan EB170 Electron Sans Ther Laboratory Incubator Lab
ITEM-37023
Jouan EB170 Electron Sans Ther Laboratory Incubator
This was removed from a working lab where it was surplus to requirements.
The unit powers up and is in good working order.
It is in reasonably good cosmetic condition with marks from use.
2 Shelves - 47 x 47cm

£ 510.00 (ex. VAT) 1 in stock
Purite Select Purification System L300150 with Storage Tank Lab
ITEM-35809
Purite Select Purification System L300150 with Storage Tank
This was removed from a university lab where it was surplus to requirements.
The system powers up and pressurises but was not tested further.
It is in reasonable cosmetic condition with marks from use.
Both filters, Pretreat 8 and Puripac PP8 expired 15/02/23
100L Storage Tank

£ 510.00 (ex. VAT) 1 in stock
Erlab Captair Store Ministore 822D Chemical Storage Safety Cabinet Lab
ITEM-30544
Erlab Captair Store Ministore 822D Chemical Storage Safety Cabinet
This was removed from a university lab where it was surplus to requirements.
The item powers on and appears to be in working condition with the fan running and air flowing from the top of the unit.
It is in good cosmetic condition with only minor marks from use.
Internal dimensions - D32 W40.5 H56cm (each side)
Shelf 32 x 40.5cm (each side)

£ 510.00 (ex. VAT) 1 in stock
Captair Erlab Model Ministore 822A - GB Cabinet Lab
ITEM-45263
Captair Erlab Model Ministore 822A - GB Cabinet Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, with fan operating.

£ 510.00 (ex. VAT) 1 in stock
Triple Red Model Duo Organic 60 Ultra Pure Water Purification System Lab
ITEM-45398
Triple Red Duo Organic 60 Ultra Pure Water Purification System
This item was removed from a university where it was surplus to requirements.
The item is in good cosmetic condition and powers on. However, we were unable to perform further testing at our facilities.
Please note: The power supply is not included. Testing was carried out using a power supply from another unit.
Included Components:
- Avidity Carbon Pre-Filter
- P/N: TR-2057
- Install Date: 26/7/23
- Avidity Cartridge Pack
- P/N: TR-2050
- Install Date: 26/7/23
- Avidity Cartridge Polisher
- P/N: TR-2051
- Install Date: 26/7/23
Specifications:
- Model: Organic 60 Ultra Pure Water Purification System
- Serial No.: Not provided

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
PolyScience 6705 Refrigerated Circulator Spares/Repair
ITEM-46442
PolyScience 6705 Refrigerated Circulator
This item was removed from a facility where it was surplus to requirements.
It powers on and is in good cosmetic condition. However, it does not circulate antifreeze, and the unit failed to reach full cooling performance, only achieving a minimum temperature of 6.0°C.
Internal inspection revealed significant corrosion on the elements.
Due to these faults, this item is listed as spares or repair.

£ POA 1 in stock
Lauda Alpha RA 8 Cooling Thermostatic Water Bath Lab Spares/Repairs
ITEM-38840
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Statebourne Bio 36 Nitrogen Dewar
ITEM-45505
This item is new in stock. Please enquire for further details.

£ POA 1 in stock
Eppendorf 5402 Refrigerated Centrifuge w/ Eppendorf F-45-18-11 Rotor Lab
ITEM-46193
This item is new in stock. Please enquire for further details.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Optima L-60 Floor Standing Centrifuge Lab Spares/Repairs
ITEM-42198
Beckman Optima L-60 Floor Standing Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
The centrifuge powers on and is in good cosmetic condition.
However, the display is not functioning correctly, showing only two dots in the TIME-HR-MIN and one dot in TEMP-°C.
Due to these issues, it is listed as Spares/Repair.
There is no rotor included.
Specifications:
- Speed: 1,000 - 60,000 rpm
- Temperature: 0°C - 40°C
Model: Optima L-60 Serial No.: L1M602
Rotational Counter: 417,132 x 10,000 rotations

£ 500.00 (ex. VAT) 1 in stock
Buchi Rotavapor R-3 w/ R-3 HB Water Bath Lab
ITEM-45189
Buchi Rotavapor R-3 w/ R-3 HB Water Bath Lab
This item was removed from a university lab where it was surplus to requirements.
It is in good cosmetic condition and in good working order.
Condenser not included.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Thermo Scientific Forma Model Type - 906 ULT Laboratory Freezer 'Spares/Repair'
ITEM-42303
Thermo Scientific Forma Model Type - 906 ULT Laboratory Freezer Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and powers on, however, when powered it displays a persistent "Wrong Power" warning with irregular compressor activity and fails to cool.
Therefore, it is listed as Spares/Repair.
Specifications.
- Model: Forma 906
- Serial#: 812688-2375
- Year: 2009

£ 500.00 (ex. VAT) 1 in stock
Taylor-Wharton LS6000 Liquid Nitrogen Cryogenic Storage Tank
ITEM-34584
This Taylor-Wharton LS6000 Liquid Nitrogen Cryogenic Storage Tank was removed from a university lab where it was surplus to requirements.
The unit appears to be in good condition, but it has not been tested.
Last service date: 06/10/2021.
Internal dimensions: 21cm x 60cm.
Capacity: 6 racks, 6000 2ml vials.

£ 500.00 (ex. VAT) 1 in stock
Jouan BR4i Refrigerated Centrifuge with S40 Rotor Lab
ITEM-46200
Jouan BR4i Refrigerated Centrifuge with S40 Rotor Lab
This item was removed from a university lab where it was surplus to requirement.
It is in good cosmetic condition and in good working order.
Includes;
- Jouan S40 Swing-Out Rotor w/ 4 x Buckets & Inserts.
- Max Load: 2kg
- Max RPM: 4300

£ 500.00 (ex. VAT) 1 in stock
Envair Bio 2+ Plus Class 2 Microbiological Safety Cabinet Lab
ITEM-31185
This Envair Bio 2 Class 2 Microbiological Safety Cabinet was removed from a laboratory where it was surplus to requirements.
The unit powers up and the airflow and light is working. The UV is not working.
Cabinet dimensions - D70 W125 H139cm
Frame dimensions - D61 W122 H83cm
Internal workspace dimensions - D56 W106 H71cm
The item is in a reasonable, used cosmetic condition.

£ 500.00 (ex. VAT) 1 in stock
Sanyo Incubator Model-MIR162 Lab
ITEM-46408
Sanyo Incubator Model-MIR162 Lab
This item was removed from a university where it was surplus to requirement.
The unit powers up and is in good working order.
It is in good cosmetic condition.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Peak Scientific HydroGen Hydrogen Generator PH600 Lab Spares/Repairs
ITEM-35068
Peak Scientific HydroGen PH600 Hydrogen Generator
This was removed from a university lab where it was surplus to requirements.
The unit does not produce hydrogen and has a service light. It starts up and it faults as it cannot achieve minimum pressure after several minutes of trying; the system check blinks with an Audible beep. It does not turn on the h2 delivery light (indicating that it is functioning).
It is in reasonable cosmetic condition with marks from use.
It is sold for spares/repairs

£ 500.00 (ex. VAT) 1 in stock
Taylor Wharton Liquid Nitrogen Dewar Model - LS3000 Lab
ITEM-41552
Taylor Wharton Liquid Nitrogen Dewar Model - LS3000 Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it at our facility.

£ 500.00 (ex. VAT) 1 in stock
Job Lot of 13 Vintage Microtome Knives With Sharpening strops and Whetstones
ITEM-42018
Job Lot of 13 Vintage Microtome Knives With Sharpening Strops and Whetstones
These items were removed from a university lab, where they were surplus to requirement.
The knife blades are all in very good condition, with sharp and undamaged cutting edges, appearing to have been well maintained, except for the hand knife, which has a poor cutting edge.
The wooden boxes are in excellent condition, except for two that are damaged.
The lot comprises:
- 3 x Shandon Nothung C wedge shape 20cm blades (circa 1967) in box
- 1 x Shandon Northung A concave 25cm blade (circa 1967) in box
- 1 x Unidentified C wedge 18cm blade in box
- 3 x MSE Ltd No. 9057.W wedge 9cm blades in box
- 2 x Cambridge Instruments rocking microtome knives (10cm blades) in box
- 1 x Unidentified wedge 8cm blade in leather case
- 1 x Hand knife with handle in poor condition in box
- 4 x Leather sharpening strops (30-35cm long), 2 in box
- 2 x 15cm whetstones
- 1 x Acrylic 15cm sharpener
- 1 x 25cm blade holder
- 3 x 20cm blade holders
- 1 x 17cm blade holder

£ 500.00 (ex. VAT) 1 in stock
HasKris Recirculating Chiller S/n HA007835 Lab Spares/Repairs
ITEM-37147
This HasKris Recirculating Chiller S/n HA007835 was removed from a university lab where it was surplus to requirements.
The unit powers up but was not tested further at our facility.
It is in good cosmetic condition, with some marks from use.
Some of the components have been removed, it is sold for spares/repairs

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter Biomek NXp Laboratory Automation Workstation Faulty Tiploader
ITEM-20384
Beckman Coulter Biomek NXp Laboratory Automation Workstation
This system was removed from a university laboratory where it was surplus to requirements.
The unit is in good cosmetic condition and powers on. We have homed the axis and successfully run a basic set of commands. A video demonstrating this functionality is available.
However, the Tiploader is faulty as it does not accept commands from the PC. Testing with a known working unit has confirmed that the issue lies with the included Tiploader, not the cable, air supply, or PC connections.
Due to the Tiploader not functioning, this system is listed as Spares/Repair.
Note:
- The head is cable tied to itself. Do not attempt to run the robot until the cables have been removed.
The system comprises the following:
- 1x Beckman Coulter Biomek NXp Laboratory Automation Workstation
- Cat no.: A31841
- Dimensions: W77 x L92 x H82 cm
- 1x IBM ThinkCentre PC
- MT-M 8143-34U
- Biomek Software Version 3.3 installed.
- 1x IBM ThinkVision Monitor
- Type: 9417-AB1
- 1x Jun-Air Compressor
- Model: 6
- Powers on with the compressor running.
- 1x Apple Pro Keyboard
- 1x Lenovo Mouse
- Box of Accessories:
- Beckman Coulter AccuFrame
- 2 Power Adaptors
- Various cables and parts
- 9 x 96 Well 0.5ml tube plates
The system is in good cosmetic condition, showing signs of use.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Heto Maxi Dry Plus VR Maxi Vacuum Centrifuge Lab Spares/Repairs
ITEM-46058
Heto Maxi Dry Plus VR Maxi Vacuum Centrifuge Lab
This item was removed from a university lab where it was surplus to requirement.
It is in reasonable condition and powers on, however there's a fault with the lock mechanism that prevents the lid from opening.
Therefore, further testing could not be conducted and it is listed as Spares/Repair.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Astell Hearson MN2950 Autoclave Lab Spares/Repairs
ITEM-20667
This was removed from a university lab where it was surplus to requirements.
It is sold for spares/repairs as the wiring has been deemed unsafe.

£ 500.00 (ex. VAT) 1 in stock
Kryo Planer Biomed 10 Series System Lab Spares/Repairs
ITEM-37143
Kryo Planer Biomed 10 Series System
This system was removed from a university where it was surplus to requirement.
The system failed PAT on insulation. It is sold for spares/repairs.
1x Kryo 10 Series Controller:
Model 10-20
1x Kryo 10 Series Controller:
Model 10-20
1x Kryo 10 series Controller Key
All units listed above power on and are in good cosmetic condition, neither have been tested further at our facility.
1x LNP4 Planer freezer Pump:
Model LNP4 13181
This item is in reasonably good cosmetic condition, but due to it requiring a separate power supply, we are unable to test it at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Limpsfield LPN3/2051 Natural Gas Burner 2051 KW/hr with Dungs Gas Valve Train
ITEM-37792
Limpsfield LPN3/2051 Natural Gas Burner 2051 KW/hr (7.0MBtu/hr)
This item was removed from a university lab where it was surplus to requirements.
The burner is in good cosmetic condition. However, the burner control screen has come apart from the control panel and is possibly broken. No testing has been carried out.
Due to the inability of testing and damaged control screen, this item is listed as Spares/Repair.
Specifications:
- Model: LPN3/2051
- Serial No.: 01333
- Manufactured: 11.09.15
- Output: 2051 KW/hr (7.0 MBtu/hr)
Includes:
- Dungs Gas Train Valve: FRS 5065 gas regulator, VPS 504 leak detector, GF 40065/3 filter
- Autoflame Combustion Management System:
- Part Nos.: MM10005, MM10004
- Serial Nos.: 20368, 051771
- TEC Fan Motor:
- 5.5KW 415 volt
- Type: 5.523TECAB35-IE3
- T3A 13251-2
- Gas Inlet Pipe: 2.5"

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
RMC CR21, CR21 Control, Transformer & Cryochamber Lab
ITEM-39828
RMC CR21, CR21 Control, Transformer & Cryochamber Lab
These items were removed from a university where they were surplus to requirement.
All the units are in reasonably good cosmetic condition. However, they cannot be tested as they all require a connection to the transformer, which is not operational.
Therefore, this listing is sold as Spares/Repair.
All items included are as follows:
Model1#: CR21 Controller
Serial1#: 10521389
Model2#: CR21 Transformer Box
Serial2#: 10521391
Model3#: CR21 Cryochamber
Serial3#: 10521390

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
VAC HE-63-P PEDATROL GloveBox Lab Spares/Repairs
ITEM-41335
VAC HE-63-P PEDATROL GloveBox Lab
This item was removed from a university where it was surplus to requirement.
It is in reasonably good cosmetic condition.
The item is missing its back panel, which prevents us from conducting tests due to exposed wires, therefore, it is sold as Spares/Repairs.
Also includes the following:
- Components for the machine
- Tubing
- Pipes
- Automatic Dewpoint Meter

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank Lab
ITEM-41441
SG Ultra Clear TUF UV Ultrapure Water System With Permeate Tank
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, we are unable to test it further at our facility.
The lab confirmed it was not in working order but were unable to confirm the fault. It is sold for spares/repairs
Included with the system is the following:
- Permeate Tank
- Cartridge Polisher
- P/N- TR-2051
- DI Cartridge
- P/N- TR-2050
- Carbon Pre-Filter
- P/N- TR-2057
- Carbon Pre-Filter (expired)
- P/N- TR-2057
- DI Cartridge (expired)
- P/N- TR-2050
- User Manual

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Lot Of 7 x Rotisserie Bottle/Tube Holders For Incubator Lab
ITEM-41459
Lot Of 7 x Rotisserie Bottle/Tube Holders For Incubator
All items are in good cosmetic condition with minimal wear
This job lot of items comes from a university lab, The items were no longer required.
None of these items have been tested at our site - it is likely that some will be spares / repairs, but we anticipate that a reasonable amount should operate well.
None of these items have been PAT or electrical safety tested. For this reason we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks.
They are sold as a spares/repairs bundle and further investment in each individual product may be required. It is an excellent opportunity for anyone looking to benefit from individual equipment resale.
The units have not been tested at all.

£ 500.00 (ex. VAT) 1 in stock
Laboratory Isolation Table - White Lab
ITEM-41681
Isolation Table - White Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition, we are unable to test it further at our facility.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Helix CTI-Cryogenics Compressor Model: SCW Part no: 8032211 Lab Spares/Repairs
ITEM-26078
This Helix CTI-Cryogenics Compressor Model: SCW Part no: 8032211 was removed from a university lab where it was surplus to requirements.
The item is in reasonable cosmetic condition but the front vent/panel is bent in one corner, preventing it from being secured. There are scratches and other marks along the surface and edges.
The unit does not power up and is sold for spares/repairs.
The absorber was last changed March 1997
Weight & dimensions are as follows:
L 52cm x W 50cm x H 42cm
75kg

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
GeneVac Technologies HT-4 Series 2 Centrifugal Evaporator Spares/Repairs
ITEM-36885
GeneVac Technologies HT-4 Series 2 Centrifugal Evaporator Centrifuge
This item was removed from a university laboratory where it was surplus to requirements.
It powers on and is in reasonable, used cosmetic condition.
The centrifuge was tested at a high spin rate and achieved approximately 1650rpm. Temperature control tests were performed; the system failed to reach the set temperatures of -20˚C and 37˚C, only stabilizing around 20˚C.
Due to the temperature faults experienced during testing, this item is listed as Spares/Repair.
Includes:
- Cart/stand: Dimensions L78 x W70 x H73 cm
- 4 x swinging buckets
- 2 x adaptors for 12 x 15ml tubes each
- 2 x adaptors for 50 x 0.5ml tubes each
- 2 x adaptors for 32 x 1.5ml tubes each (PN-10-5043)
Specifications.
- Model: HT4 Series 2
- Serial No.: 5794
This system does not include a vacuum pump.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
New Brunswick Scientific U570-86 Ultra Low Temperature Freezer Lab Spares/Repair
ITEM-45126
New Brunswick Scientific U570-86 Ultra Low Temperature Freezer Lab
This item was removed from a university laboratory where it was surplus to requirements.
The item powers on and is in a reasonable used cosmetic condition.
It includes 4 shelves but has only 4 pegs, so only one shelf can be fitted currently. There are only two doors at the bottom.
During testing, the freezer was set to its minium temperature of -86ºc, but would not drop below -19ºc.
Therefore, it is listed as Spares/Repair and no further testing was conducted.
Specifications:
- Model: U570 -86
- Serial No.: 1004-5204-1103

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Sanyo CO2 Incubator MCO-17AIC Lab Spares/Repairs
ITEM-39947
Sanyo CO2 Incubator MCO-17AIC
This was removed from a university lab where it was surplus to requirements.
The unit powers up but has an issue with CO2 leaking.
It is sold for spares/repairs.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf Refrigerated Centrifuge 5804 R Lab Spares/Repairs
ITEM-41484
Eppendorf Refrigerated Centrifuge 5804 R Lab
This item was removed from a university where it was surplus to requirement.
It is in good cosmetic condition but does not power on, therefore we are unable to test it further, and it is listed as Spares/Repair.
The control board is faulty, and is loose inside the chamber.
There is no rotor.

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Eppendorf 5804 R Centrifuge Lab Spares/Repairs
ITEM-45431
Eppendorf 5804 R Centrifuge Lab
This item was removed from a university where it was surplus to requirements.
The centrifuge powers on and is in good cosmetic condition. However, it displays "Error 14," indicating an electrical fault, and also has a faulty lid locking mechanism.
Due to both errors listed above, this item is listed as Spares/Repair.
Specifications:
- Model: 5804 R
- Serial No.: 5805CI964308

SPARES/REPAIR ITEM
SPARES/REPAIR ITEM
£ 500.00 (ex. VAT) 1 in stock
Beckman Coulter BioMek FXP Laboratory Automation Workstation System Faulty
ITEM-39234
Beckman Coulter BioMek FXP Laboratory Automation Workstation System
This system was removed from a university where it was surplus to requirement.
It is in good cosmetic condition and powers on, although due to the following error; "D1 axis error:pump failed to send boot request. (0512)."
we are unable to test it further, and it is listed as Spares/Repair. We suspect the tip loader is faulty.
This error prevents the system from connecting to the software.
This system also includes the following:
- Beckman Coulter Accuframe
- Thomas 669BESUU44TFE Pump
- BioTek Valve Module
- All relevant manuals and guides
- Sami WorkStation EX Software 4.0
- Software setup guide
- 2 x 96 well tip holders with all tips present
- 2 x light curtain test rods
- Filter regulator NAW2000-N02D-C
- 2 x boxes of spare parts and replacement parts
- 9 x bottles
- pipes and connectors for bottles
- PC + Monitor
- Keyboard
- Microscan MS3